NHTSA safety recall

Recall 03V043000

Electrical System › Alternator/generator/regulator — Pierce · reported 12 Feb 2003 · 13 vehicles potentially affected

What's wrong

ON CERTAIN FIRE CHASSIS EQUIPPED WITH HARRISON HYDRA-GEN GENERATORS. THE TUBING CONNECTING THE SOFT START TO THE GENERATOR PUMP CAN BREAK AWAY FROM THE FITTING AND SPRAY HYDRAULIC FLUID ONTO THE EXHAUST.

The risk

THIS CAN CAUSE A FIRE THAT COULD ENDANGER PEOPLE IN THE VICINITY, THE VEHICLE ITSELF, AND NEARBY PROPERTY.

The fix

DEALERS WILL REMOVE TWO PIECES OF STEEL TUBING AND REPLACE THEM WITH HIGH PRESSURE HOSE. OWNER NOTIFICATION IS EXPECTED TO BEGIN DURING FEBRUARY 2003. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT PIERCE AT 1-888-974-3723.

CUSTOMERS CAN ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-888-DASH-2-DOT (1-888-327-4236).

NHTSA campaign
03V043000
Filed by
Pierce Manufacturing,inc.
Report received
12 Feb 2003
Owners notified
24 Feb 2003
Potentially affected
13

Vehicles covered by this recall

Whether a particular car is affected and still unrepaired depends on its VIN — a model year being listed does not mean every car of that year is included. Check any VIN free on CarLogs, or at nhtsa.gov/recalls.

2000 Pierce Fire Truck

Is this car's recall fixed?

Recall repairs are free at any franchised dealer, for the life of the vehicle. A CarLogs report shows the recall status for a specific VIN as reported by the manufacturer — whether it's open or repaired, and whether the fix is available yet.