Recall 20V812000 · manufacturer campaign 20V-762
Electrical System › Instrument Cluster/panel — Spartan Fire · reported 28 Dec 2020 · 2 vehicles potentially affected
What's wrong
Marion Body Works Inc. is recalling certain 2020 Spartan Gladiator and MetroStar vehicles equipped with Weldon V-Mux Vista IV Standard LCD displays used for controlling emergency vehicle lighting and HVAC functions. These displays may experience low voltage spikes, and cause the LCD display to lock up or become nonfunctional, due to varying electrical installations.
The risk
If the LCD display becomes locked up or non-functional it can delay emergency efforts, which can increase the risk of injury.
The fix
Marion Body Works will notify owners, and dealers will replace the IV Standard LCD displays, free of charge. The recall began January 19, 2021. Owners may contact Marion Body Works customer service at 1-715-754-5261. Marion Body Works' number for this recall is 20V-762.
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
Vehicles covered by this recall
Whether a particular car is affected and still unrepaired depends on its VIN — a model year being listed does not mean every car of that year is included. Check any VIN free on CarLogs, or at nhtsa.gov/recalls.
Is this car's recall fixed?
Recall repairs are free at any franchised dealer, for the life of the vehicle. A CarLogs report shows the recall status for a specific VIN as reported by the manufacturer — whether it's open or repaired, and whether the fix is available yet.
Source: NHTSA Office of Defects Investigation recall database. Look up another campaign →