Structure — Am General · reported 28 Apr 1977 · 2,270 vehicles potentially affected
What's wrong
THE INVOLVED VEHICLES DO NOT CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". WHEN SUBJECTED TO A 30 M.P.H. FIXED BARRIER COLLISION TEST, THE FRAME SIDE RAILS COLLAPSED AND THE BRACKETRY ATTACHED TO ONE OF THE RAILS SUPPORTING THE FUEL ASSEMBLY RUPTURED OR PUNCTURED THE FUEL TANK. THIS COULD ALLOW EXCESSIVE FUEL SPILLAGE.
The fix
DEALER WILL REMOUNT THE FUEL TANK TO THE BODY FLOOR PAN AND STRUCTURE, AND SHIELD THE FRAME REINFORCEMENT TO PREVENT PENETRATION.
VEHICLE DESCRIPTION: LIGHT TRUCKS.SYSTEM: STRUCTURE; FRAME SIDE RAILS.CONSEQUENCES OF DEFECT: FUEL SPILLAGE, RESULTING FROM A VEHICLE IMPACT, COULDLEAD TO A VEHICLE FIRE AND SERIOUS PASSENGER INJURIES.