NHTSA safety recall

Recall 79V072000

Structure — Heil · reported 16 Mar 1979 · 8 vehicles potentially affected

What's wrong

THE GIRTH SEAM MAY DEVELOP A CRACK WHICH CAN CONTINUE TO GROW UNTIL THE TANK FAILS, BRINGING THE TRAILER TO A STOP.

The fix

REPAIRS WILL CONSIST OF A LAPPER BAND BEING PLACED OVER THE GIRTH SEAM AND THE INSTALLATION OF FITTINGS WHICH CAN BE AIR TESTED TO DETERMINE IF A FAILURE IS DEVELOPING.

VEHICLE DESCRIPTION: TRAILERS, TANK.SYSTEM: STRUCTURE; CHEMICAL TANK.CONSEQUENCES OF DEFECT: IF THE TRAILER STOPS SUDDENLY, A TRAFFIC HAZARD WOULDEXIST WITH A HIGH POSSIBILITY OF A VEHICLE ACCIDENT. ALSO, THE RELEASE OFHAZARDOUS MATERIAL IN THE TANK CAN CAUSE SERIOUS PERSONAL INJURY.NOTE: FAILURE CANNOT BE DETECTED BECAUSE THE CONTENTS DO NOT LEAK FROM A CRACKIN THE AFFECTED AREA OF THE TANK.

NHTSA campaign
79V072000
Filed by
Heil Company
Report received
16 Mar 1979
Potentially affected
8

Vehicles covered by this recall

Whether a particular car is affected and still unrepaired depends on its VIN — a model year being listed does not mean every car of that year is included. Check any VIN free on CarLogs, or at nhtsa.gov/recalls.

1978 Heil Heil

Is this car's recall fixed?

Recall repairs are free at any franchised dealer, for the life of the vehicle. A CarLogs report shows the recall status for a specific VIN as reported by the manufacturer — whether it's open or repaired, and whether the fix is available yet.

Source: NHTSA Office of Defects Investigation recall database. Look up another campaign →