Recall 88V120000
Equipment › Electrical — Avion · reported 25 Jul 1988 · 499 vehicles potentially affected
What's wrong
THE GROUNDING LUG ATTACHED TO THE METAL CASE OF THE 120VAC/12VDC POWER CONVERTER DOES NOT HAVE REQUIRED GROUNDING CONDUCTOR CONNECTED TO THE CHASSIS GROUND SYSTEM.
The risk
AN ELECTRICAL SHOCK HAZARD MAY EXIST IF AN INSULATIONFAILURE OF A CONDUCTOR INSIDE THE CONVERTER SHOULD OCCUR.
The fix
INSTALL CONVERTER CASE GROUND CONDUCTOR.
SYSTEM: ELECTRICAL/GROUNDING CONDUCTOR.VEHICLE DESCRIPTION: TRAVEL TRAILERS.
Vehicles covered by this recall
Whether a particular car is affected and still unrepaired depends on its VIN — a model year being listed does not mean every car of that year is included. Check any VIN free on CarLogs, or at nhtsa.gov/recalls.
Is this car's recall fixed?
Recall repairs are free at any franchised dealer, for the life of the vehicle. A CarLogs report shows the recall status for a specific VIN as reported by the manufacturer — whether it's open or repaired, and whether the fix is available yet.
Source: NHTSA Office of Defects Investigation recall database. Look up another campaign →