NHTSA safety recall

Recall 93V199000 · manufacturer campaign 94-C-09 / 94-C-01

Fuel System, Gasoline › Delivery › Hoses, Lines/piping, And Fittings — Chevrolet, Pontiac · reported 1 Dec 1993 · 6,807 vehicles potentially affected

What's wrong

THE FUEL LINES ON THESE VEHICLES MAY HAVE BEEN MISROUTED AND MAY CONTACT THE "AIR" CHECK VALVE. THE HIGH TEMPERATURES FROM THE "AIR" CHECK VALVE COULD ALLOW IT TO MELT THROUGH AND DAMAGE A FUEL LINE.

The risk

A FUEL LINE WHICH HAS BEEN DAMAGED BY THE HEAT OF THE"AIR" CHECK VALVE MAY LEAK FUEL INTO THE ENGINE COMPARTMENT WHERE IT COULDRESULT IN A FIRE IF EXPOSED TO A SOURCE OF IGNITION.

The fix

REROUTE ANY MISROUTED FUEL LINES TO THE PROPER POSITION, AND REPLACE ANY FUEL LINE BUNDLE WHERE THE OUTER SHELL HAS BEEN MELTED THROUGH.

GM RECALL NUMBERS:CHEVROLET IS 94-C-09 AND PONTIAC IS 94-C-01.SYSTEM: FUEL; FUEL LINES; HOSES; NON-METALLIC.VEHICLE DESCRIPTION: PASSENGER CARS WITH 5.7 LITER V8 ENGINES.NOTE: IF YOUR VEHICLE IS PRESENTED TO AN AUTHORIZED DEALER ON AN AGREED UPONSERVICE DATE AND THE REMEDY IS NOT PROVIDED WITHIN A REASONABLE TIME OR THEREMEDY DOES NOT CORRECT THE DEFECT OR NONCOMPLIANCE, PLEASE CALL CHEVROLETSERVICE CENTER AT 1-800-222-1020 OR PONTIAC SERVICE CENTER AT 1-800-762-2737.ALSO, PLEASE CALL THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTOSAFETY HOTLINE AT 1-800-424-9393.

NHTSA campaign
93V199000
Manufacturer campaign
94-C-09 / 94-C-01
Filed by
General Motors Corp.
Report received
1 Dec 1993
Owners notified
8 Dec 1993
Potentially affected
6,807

Vehicles covered by this recall

Whether a particular car is affected and still unrepaired depends on its VIN — a model year being listed does not mean every car of that year is included. Check any VIN free on CarLogs, or at nhtsa.gov/recalls.

Is this car's recall fixed?

Recall repairs are free at any franchised dealer, for the life of the vehicle. A CarLogs report shows the recall status for a specific VIN as reported by the manufacturer — whether it's open or repaired, and whether the fix is available yet.

Source: NHTSA Office of Defects Investigation recall database. Look up another campaign →