NHTSA safety recall

Recall 95V188001

Fuel System, Other › Storage › Tank Assembly › Pressure Relief Devices — Neoplan · reported 30 Aug 1995 · 101 vehicles potentially affected

What's wrong

SOME TEMPERATURE SENSITIVE TRIGGERS WERE NOT X-RAYED. THESE TRIGGERS COULD CONTAIN INTERNAL VOIDS THAT WOULD MAKE THE TRIGGERS SUSCEPTIBLE TO ADVANCED CREEP CAUSING FALSE ACTIVATION AND VENTING OF THE CNG.

The risk

VENTING OF THE CNG COULD RESULT IN A FIRE.

The fix

NEOPLAN WILL REPLACE THE PRD WITH THE NEWER DESIGN "GENERATION 2.5" PRESSURE RELIEF DEVICE.

SYSTEM: FUEL; CNG; PRESSURE RELIEF VALVES/DEVICES (PRD).VEHICLE DESCRIPTION: COMPRESSED NATURAL GAS POWERED TRANSIT BUSES EQUIPPED WITH LINCOLN COMPOSITE CNG FUEL CONTAINERS WHICH INCORPORATE MIRADA TYPE IIIPRESSURE RELIEF VALVES. (SEE MIRADA CAMPAIGN 95E025 AND LINCOLN COMPOSITE CAMPAIGN 95E025003).NOTE: IF THE VALVES HAVE NOT BEEN REPLACED WITHIN A REASONABLE TIME FREE OF CHARGE, PLEASE CONTACT NEOPLAN AT 1-719-336-3256.ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.

NHTSA campaign
95V188001
Filed by
Neoplan Usa Corp.
Report received
30 Aug 1995
Owners notified
15 Dec 1995
Potentially affected
101

Vehicles covered by this recall

Whether a particular car is affected and still unrepaired depends on its VIN — a model year being listed does not mean every car of that year is included. Check any VIN free on CarLogs, or at nhtsa.gov/recalls.

1991 Neoplan An440 1992 Neoplan An440 1994 Neoplan An440 1995 Neoplan An440

Is this car's recall fixed?

Recall repairs are free at any franchised dealer, for the life of the vehicle. A CarLogs report shows the recall status for a specific VIN as reported by the manufacturer — whether it's open or repaired, and whether the fix is available yet.

Source: NHTSA Office of Defects Investigation recall database. Look up another campaign →